首页 新能源 查看内容

IEC 61851-21-2 大功率 充电桩 辐射 传导 测试

摘要:  IEC 61851-21-2:2018 Electric vehicle conductive charging system - Part 21-2: Electric vehicle requirements for conductive connection to an AC/DC supply - EMC requirements for off board electric vehicl ...

IEC 61851-21-2:2018
Electric vehicle conductive charging system - Part 21-2: Electric vehicle requirements for conductive connection to an AC/DC supply - EMC requirements for off board electric vehicle charging systems

充电桩辐射研究

充电桩传导发射研究

Radiated emissions limits for Class B equipment
Frequency Range (MHz)
Distance (m)
Detector type and RBW
Class B Limits (dBμV/m)
30-230
10
Quasi-peak (120kHz)
30
230-1000
10
Quasi-peak (120kHz)
37
1000 to 3000
3
Average (1MHz)
50
3000 to 6000
3
Average (1MHz)
54
1000 to 3000
3
Peak (1MHz)
70
3000 to 6000
3
Peak (1MHz)
74

Conducted emissions limits for Class B equipment for AC power line
Frequency Range (MHz)
Quasi-peak (dBμV)
Average (dBμV)
0.15 to 0.50
66
Decreasing linearly with logarithm of frequency to 56
56
Decreasing linearly with logarithm of frequency to 46
0.50 to 5.0
56
46
5.0 to 30.0
60
50

DC charging immunity requirements (non-residential environments)
Test applicability
Phenomenon
Basic standard
Test specification
Units
Waiting
Radiated RF
IEC 61000-4-3
10
V/m
(stand-by mode)
field
[16]
80-1000
MHz



80
% AM (1 kHz)
Waiting
Radiated RF
IEC 61000-4-3
3
V/m
(stand-by mode)
field
[16]
1400-2000
MHz



80
% AM (1 kHz)

IEC 61851-21-2-2018
电动汽车导电充电系统. 第21-2部分: 交流/直流电源导电连接的电动汽车要求. 车外电动汽车充电系统的电磁兼容性要求
IEC 61851-21-2-2018大型充电桩辐射、传导研究测试报告,请参阅 https://dzfa.com/thread-5307-1-1.html  151 0200 1358 (微信同号)

如果文章对你有帮助,欢迎点击上方按钮打赏作者

关闭

赞助商上一条 /2 下一条